XPress AutomationTM

XPress Automation

Enables Control of CGXPress with a Master Control Automation or Newsroom Automation System.

XPress Automation allows an external computer to control the CGXPress character generator via either an RS-232 or RS-422 serial connection.

Includes the utility AutoTest to allow easy setup and configuration of the Automation System.


Description

XPress AutomationTM supports the industry standard Chyron Intelligent Interface protocol to allow the following functions to be controlled via automation:

Time & Temperature Display
Crawl Updates
Set Message Directory
Recall Message
Transfer Message
Change Message
Tab Update
Erase Message

Xpress Automation Supported Commands
KEYPADCLR 	Clears the keyboard address to 0000
ERASE 		Erases the current document
CNTL 		Control Prefix
CHNG 		Exchange assignment Preview <--> Air
READ 		Read a file into current display buffer
READNEXT 	Read the next available message
XFER 		Exchange Program and Preview
CHYESC        	Erase the canvas
ALT           		Prefix to increment or decrement Keypad Value
LEFTARROW <8C>    	Used with ALT key to decrement Keypad Value
RIGHTARROW <8D>   	Used with ALT key to increment Keypad Value
DELMSG        	Delete Message, used with crawl text

Sub Commands
ALT LEFTARROW	Decrement Keypad Value
ALT RIGHTARROW	Increment Keypad Value
CNTL D		Change Directory
CNTL CHNG	Exchange assignment Preview <--> Air
CNTL XFER	Transfers VGA output to Air

Infinit Keypad Codes
KEYPAD0 		converted to ASCII 0
KEYPAD1 		converted to ASCII 1
KEYPAD2 		converted to ASCII 2
KEYPAD3 		converted to ASCII 3
KEYPAD4 		converted to ASCII 4
KEYPAD5 		converted to ASCII 5
KEYPAD5 		converted to ASCII 6
KEYPAD7 		converted to ASCII 7
KEYPAD8 		converted to ASCII 8
KEYPAD9 		converted to ASCII 9

Xpress Automation Responses

If a request for acknowledge <05> is embedded in a command a "*"
will be returned if the command is completed without error.

Error Codes
If an error is detected, a 4-byte ASII error code is transmitted, followed by a
carriage return and line feed.  If no error is detected and the command was
processed successfully an asterisk (ASCII 42) followed by a carriage return
and line feed is transmitted.

The list of Xpress error codes is shown below.

0001	Task Timed out
0002	Unimplemented System Service
0003	Illegal Service
0009	Object Not Found
0014	Cannot Create Message
0024	Cannot Delete
0052	Cannot Create or Send
2010	Null Filename
2011	File Already Exists
2040	Used Tab Page
2F01	Insufficient Data Area
40B2	Requested Message Directory Doesn't Exist
40B3	Requested Message File Does not Exist
412E	Requested Field is Not a Valid Field
415F	Number of Tabs Exceeds Limit (99)
4190	Desired Operation is Not Terminated With "\\"
4191	The command Format is Incorrect
4192	An Invalid Operation Has Been Requested
4193	An Invalid Machine ID Has Been Used
41C5	An Invalid Frame Buffer ID Was Used
41CD	Timed Out Waiting for Response
41CF	Error Erasing Displaying Frame Buffer
41D0	Display/Non-/Display Flag out of Range
41D1	No Intelligent interface Option